Summary for Test 2021-05-13-8-1
Test performed: ASTM A970-15e1Project Information
| Project Identifiers | Project ID: 214355 DEA: 120K0214 EFIS: 1214000096 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-5-12.4/14.5 |
| Award Date | 12/20/2019 |
| Closeout Date | 10/02/2025 |
| Work Description | South County Improvement Project (Phase 1 - Avery/Crown Valley) PLACE HMA, INSTALL CONC PAVEMENT, RETAIN WALL, MODIFY ELECT SYS. | Add one lane btwn 73 & Oso PKWY |
| Location Description | ORANGE COUNTY IN SAN JUAN CAPISTRANO, LAGUNA HILLS, LAGUNA NIGUEL AND MISSION VIEJO FROM 0.5 MILE SOUTH OF AVERY PARKWAY UNDERCROSSING TO 0.8 MILE NORTH OF CROWN VALLEY PARKWAY OVERCROSSING |
| QA Service Level | 1 (Verified on 10/31/2019) |
Sample Information
| Sample Taken Date | 05/13/2021 | Sample Unique Key | 8 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2021 |
| Sample type | Quality Assurance | A brief description of the sample | nVent LENTON TERMINATOR (D14) with LENTON PLUS cold worked taper threaded rebar |
| The quantity of what the sample constitutes | (8) nVent LENTON TERMINATOR (D14) with LENTON PLUS cold worked taper threaded rebar | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Rigoberto | Last name of sampler or witnessed by | Marin |
| Title of sampler | AMR | Telephone number of sampler | 951-500-0685 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Coreslab Structures L A Inc | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L133-059-21 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 4102817 | Head Manufacturer Lot Number(s) | L9805 L9766 |
| Rebar Size | #8 | Headed Bar Model Name | 9TT 17 02 |
| Size of Head | Full Size - 9x | Head Connection Type | Taper Threaded |
| Head Shape | Circular | Rebar Manufacturer | CMC Steel Arizona |
| Head Manufacturer | ERICO International Corporation nVent | Head Fabricator | nVent Lenton |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2021-05-13-8
DIME Test ID: 2021-05-13-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2021-05-18
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 05/14/2021
UTM: 400kip
Temperature: 72 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 1 | 0.79 | 78540 | 99418 | Head Pull Off | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Head Pull Off
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 5/18/2021 ✔