Summary for Test 2021-03-26-16-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 213808
DEA: 080N6704
EFIS: 0800000536
DIST-CO-RTE-PM08-RIV-74-28.1/37.4
Award Date03/12/2019
Closeout Date04/28/2022
Work DescriptionCONSTRUCT RAISED MEDIAN AND LEFT TURN LANES.
Location DescriptionRIVERSIDE COUNTY NEAR HEMET FROM 0.6 MILE EAST OF ROUTE 215 TO 0.4 MILE WEST OF ACACIA AVENUE.
QA Service Level1 (Verified on 12/04/2019)

Sample Information

Sample Taken Date03/26/2021 Sample Unique Key16
Date that the sample was received by the laboratory/organization performing the testing03/29/2021 Sample typeDepartment Acceptance
A brief description of the sample3/4" HMA-A R24 PG64-28M (0.50% LAS) The quantity of what the sample constitutes60.74 Tons
From where was the sample collectedManufacturer First name of sampler or witnessed byKevin
Last name of sampler or witnessed byOluoha Title of sampler
Telephone number of sampler Laboratory sample identification0176A-21
Linked DIME Sample ID The fabricator/manufacturer/facility nameCCA-Lake Elsinore
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot numberUnknown
Sublot numberUnknown HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2021-03-26-16
DIME Test ID: 2021-03-26-16-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-04-07

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 04/02/2021
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 4.44 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/7/2021 ✔