Summary for Test 2021-03-26-11-8
Test performed: AASHTO T304-11Project Information
Project Identifiers | Project ID: 213707 DEA: 081C38U4 EFIS: 0817000196 |
---|---|
DIST-CO-RTE-PM | 08-RIV-10-6.7/R25.1 |
Award Date | 11/26/2019 |
Closeout Date | 11/01/2023 |
Work Description | Remove concrete pavement and base, and place HMA and JPCP |
Location Description | ROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON. |
QA Service Level | 1 (Verified on 01/09/2020) |
Sample Information
Sample Taken Date | 03/26/2021 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/29/2021 |
Sample type | Verification | A brief description of the sample | PSUE 3/8" HMA-A-SP R15 0.5% LAS |
The quantity of what the sample constitutes | 6 Bags of Combined, 3 Bags of RAP | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Oluoha |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0175A-21 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | California Commercial Asphalt - Lake Elsinore | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0098, 91-33-0011 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 3/8 HMA-A-SP R15 | The fabricator/manufacturer designation for the sample | |
The plant number | 53891193 | A detailed description of where the material sample was collected | Belt Cut at California Commercial Asphalt Lake Elsinore Plant |
Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 3/8 inch |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-03-26-11
DIME Test ID: 2021-03-26-11-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2021-04-09
Test Results
What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Michael Magana
Date of test: 04/05/2021
Bulk dry specific gravity: 2.548
Average uncompacted voids: 47.5 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/9/2021 ✔