Summary for Test 2021-03-29-11-2
Test performed: AASHTO T176-08Project Information
Project Identifiers | Project ID: 213707 DEA: 081C38U4 EFIS: 0817000196 |
---|---|
DIST-CO-RTE-PM | 08-RIV-10-6.7/R25.1 |
Award Date | 11/26/2019 |
Closeout Date | 11/01/2023 |
Work Description | Remove concrete pavement and base, and place HMA and JPCP |
Location Description | ROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON. |
QA Service Level | 1 (Verified on 01/09/2020) |
Sample Information
Sample Taken Date | 03/29/2021 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/28/2021 |
Sample type | Quality Assurance | A brief description of the sample | 3/8" HMA Aggregate |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Oluoha |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 1 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | CCA Lake Elsinore | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0098, 91-33-0011 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Belt Cut at California Commercial Asphalt Lake Elsinore Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
The concrete mix design number | 53891193 | Lot number | |
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-03-29-11
DIME Test ID: 2021-03-29-11-2
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2021-04-06
Test Results
How many times will the test be run?: 3 Times
Input Type: Calculated
Tester's full name: A. Nguyen
Date of test: 03/29/2021
Sand Equivalent (Test 1): 72
Sand Equivalent (Test 2): 80
Sand Equivalent (Test 3): 79
Sand Equivalent: 77
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/6/2021 ✔