Summary for Test 2021-03-06-5-3

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 214340
DEA: 081G2914
EFIS: 0818000114
DIST-CO-RTE-PM08-SBD-10-27.9
Award Date05/22/2020
Closeout Date11/01/2021
Work DescriptionWIDEN EB OFF RAMP
Location DescriptionSAN BERNARDINO COUNTY IN REDLANDS AT CALIFORNIA STREET EASTBOUND EXIT RAMP
QA Service Level1 (Verified on 07/16/2020)

Sample Information

Sample Taken Date03/06/2021 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing03/07/2021 Sample typeDepartment Acceptance
A brief description of the sampleRSC Flexural Beams The quantity of what the sample constitutes3 beams
From where was the sample collectedManufacturer First name of sampler or witnessed byQC
Last name of sampler or witnessed byQC Title of sampler
Telephone number of sampler Laboratory sample identification1RA,1RB,1RC
Linked DIME Sample ID The fabricator/manufacturer/facility nameRobertsons Redlands
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSM446B39
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedTT-1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete sample from wheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-03-06-5
DIME Test ID: 2021-03-06-5-3
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2021-03-24

Test Results


Number of specimens: 1
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: J. Diaz
Date of test: 03/16/2021
Identification number: 1RC
Width of specimen: 6.0625 inch
Depth of specimen: 6.0625 inch
Span length of specimen: 18 inch
Maximum load applied: 9620 lb
Curing history and apparent moisture condition of the specimen: Sand Pit
If specimen was capped, ground or if leather shims were used: yes
Defects in specimen, including numbers of beams discarded during test: No
Age of specimen: 10 days
Age of specimen in hours: no data
Modulus of rupture: 820 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/24/2021 ✔