Summary for Test 2020-09-02-39-5

Test performed: AASHTO T283-14

Project Information

Project IdentifiersProject ID: 214875
DEA: 033H72U4
EFIS: 0320000087
DIST-CO-RTE-PM03-BUT-70-5.6/9.1
Award Date06/16/2020
Closeout Date08/10/2023
Work DescriptionROADWAY EXCAVATION, PLACE HMA & RHMA, & CONSTRUCT DRAINAGE SYSTEMS.
Location DescriptionBUTTE COUNTY NEAR OROVILLE FROM 0.2 MILE NORTH OF COX LANE TO 0.1 MILE NORTH OF PALERMO ROAD
QA Service Level1 (Verified on 04/15/2020)

Sample Information

Sample Taken Date09/02/2020 Sample Unique Key39
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/03/2020
Sample typeVerification A brief description of the sample3/4" HMA - A w/RAP
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byBrad Last name of sampler or witnessed byMckeehan (WITNESS)
Title of samplerKRC Personnel Telephone number of sampler
Laboratory sample identificationJMF20-038 Linked DIME Sample ID
The fabricator/manufacturer/facility nameKnife River Construction - Hallwood Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2020-09-02-39
DIME Test ID: 2020-09-02-39-5
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2021-02-01

Test Results


Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 09/11/2020
Wet 1Wet 2Wet 3Dry 1Dry 2Dry 3
Untreated

152 psi

196 psi

0.78
General comments (publicly viewable) (Max 1000 characters): JMF20-038. Test date estimated.