Summary for Test 2021-01-22-1-4

Test performed: CTM 553-1

Project Information

Project IdentifiersProject ID: 213596
DEA: 051C8904
EFIS: 0513000009
DIST-CO-RTE-PM05-MON-101-87.3/R91.5
Award Date12/13/2018
Closeout Date08/23/2023
Work DescriptionPRECAST CONC PVMT, CRACK AND SEAT PAVEMENT AND RECONSTRUCT RAMPS.
Location DescriptionMONTEREY COUNTY IN SALINAS FROM EAST MARKET STREET UNDERCROSSING TO 0.3 MILE SOUTH OF ESPINOSA ROAD
QA Service Level1 (Verified on 01/04/2019)

Sample Information

Sample Taken Date01/22/2021 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing01/22/2021 Sample typeQuality Assurance
A brief description of the sampleRapid Setting Cement The quantity of what the sample constitutes1 Bucket
From where was the sample collectedSupplier First name of sampler or witnessed byna
Last name of sampler or witnessed byna Title of sampler
Telephone number of sampler Laboratory sample identificationCM214101
Linked DIME Sample ID The fabricator/manufacturer/facility nameCTS Rapid Set
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandCTS
MillJuarez Type of Cementitious MaterialRapid Set Cement

Test Details

DIME Sample ID: 2021-01-22-1
DIME Test ID: 2021-01-22-1-4
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: CTM 553-1: Method for Testing Thermal Stability of Mortar Made with Hydraulic Cement
Test Release Date: 2021-02-09

Test Results


Input Type: Calculated
Tester's full name: Benjamin Lenz
Date of test: 01/29/2021
Average of test specimens broken to nearest 50 kPa, 23 ± 1.7°C for 48h: 39300 kPa
Average of test specimens broken to nearest 50 kPa, 50 ± 1°C for 48h: 36800 kPa
Thermal stability ratio: 94
General comments (publicly viewable) (Max 1000 characters): 3 day test -- Two specimen breaks were outside allowable range per Section 13 of ASTM C109-16. Average compressive strength shown is based on remaining 4 specimens.

Test was verified on 2/9/2021 ✔