Summary for Test 2021-01-22-1-4
Test performed: CTM 553-1Project Information
| Project Identifiers | Project ID: 213596 DEA: 051C8904 EFIS: 0513000009 |
|---|---|
| DIST-CO-RTE-PM | 05-MON-101-87.3/R91.5 |
| Award Date | 12/13/2018 |
| Closeout Date | 08/23/2023 |
| Work Description | PRECAST CONC PVMT, CRACK AND SEAT PAVEMENT AND RECONSTRUCT RAMPS. |
| Location Description | MONTEREY COUNTY IN SALINAS FROM EAST MARKET STREET UNDERCROSSING TO 0.3 MILE SOUTH OF ESPINOSA ROAD |
| QA Service Level | 1 (Verified on 01/04/2019) |
Sample Information
| Sample Taken Date | 01/22/2021 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/22/2021 |
| Sample type | Quality Assurance | A brief description of the sample | Rapid Setting Cement |
| The quantity of what the sample constitutes | 1 Bucket | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | na | Last name of sampler or witnessed by | na |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | CM214101 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | CTS Rapid Set | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Cementitious | Brand | CTS |
|---|---|---|---|
| Mill | Juarez | Type of Cementitious Material | Rapid Set Cement |
Test Details
DIME Sample ID: 2021-01-22-1
DIME Test ID: 2021-01-22-1-4
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: CTM 553-1: Method for Testing Thermal Stability of Mortar Made with Hydraulic Cement
Test Release Date: 2021-02-09
Test Results
Input Type: Calculated
Tester's full name: Benjamin Lenz
Date of test: 01/29/2021
Average of test specimens broken to nearest 50 kPa, 23 ± 1.7°C for 48h: 39300 kPa
Average of test specimens broken to nearest 50 kPa, 50 ± 1°C for 48h: 36800 kPa
Thermal stability ratio: 94
General comments (publicly viewable) (Max 1000 characters): 3 day test -- Two specimen breaks were outside allowable range per Section 13 of ASTM C109-16. Average compressive strength shown is based on remaining 4 specimens.
Test was verified on 2/9/2021 ✔