Summary for Test 2021-12-03-39-5
Test performed: CTM 203-February 2008
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Please click this
link
to view the corrected test.
Project Information
| Project Identifiers | Project ID: 212779 DEA: 021H5804 EFIS: 0216000024 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-70-58.4/R78.4 |
| Award Date | Not set |
| Closeout Date | 10/03/2025 |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
| Sample Taken Date | 12/03/2021 | Sample Unique Key | 39 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/06/2021 |
| Sample type | Preliminary | A brief description of the sample | 1 bag of soil for use in geogrid embankment design |
| The quantity of what the sample constitutes | Existing soil at 02-PLU-70-58.9 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Scott | Last name of sampler or witnessed by | Lewis |
| Title of sampler | Engineering Geologist | Telephone number of sampler | (530) 225-3516 |
| Laboratory sample identification | D78983 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | N/A | Transportation Laboratory (TL) Number | 876433 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-PLU-70-58.92 from slope on North side of road, 0 to 0.83 ft. depth | |
| Where the material sample would have been placed if not sampled | In situ |
Test Details
DIME Sample ID: 2021-12-03-39
DIME Test ID: 2021-12-03-39-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 203-February 2008: Mechanical Analysis of Soils
Test Release Date: 2022-01-20
Test Results
What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Calculated
Tester's full name: Natalie Rivinius and K. R.Dorado
Date of test: 01/08/2022
Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 92 %
Cumulative percent passing the 1 in. sieve: 92 %
Cumulative percent passing the 3/4 in. sieve: 90 %
Cumulative percent passing the 1/2 in. sieve: 88 %
Cumulative percent passing the 3/8 in. sieve: 86 %
Cumulative percent passing the #4 sieve: 82 %
Cumulative percent passing the #8 sieve: 80 %
Cumulative percent passing the #16 sieve: 76 %
Cumulative percent passing the #30 sieve: 73 %
Cumulative percent passing the #50 sieve: 69 %
Cumulative percent passing the #100 sieve: 63 %
Cumulative percent passing the #200 sieve: 58 %
Cumulative Percent Passing on 5 Microns: 22 %
Cumulative Percent Passing on 1 Micron: 34 %
General comments (publicly viewable) (Max 1000 characters): The presence 1½″ particles in a relatively small sample could cause the percentage of the sample reported passing the coarser sieves to not accurately represent the general population. A few additional or missing large stones can shift the entire gradation up or down proportionately.
Test was verified on 1/20/2022 ✔
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.