Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-12-29-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210735
DEA: 071193U4
EFIS: 0713000007
DIST-CO-RTE-PM07-LA-10-37.2/42.4
Award Date11/16/2015
Closeout Date07/11/2022
Work DescriptionCONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location DescriptionIN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA
QA Service Level1 (Verified on 03/07/2016)

Sample Information

Sample Taken Date12/29/2016 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/09/2017
Sample typeQuality Assurance A brief description of the sampleHRC 110 End Anchors
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byGreg Last name of sampler or witnessed byJohnston
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHRC CMC Rebar Nucor Transportation Laboratory (TL) NumberC731322
Inspector Lot Number from the Transportation Laboratory (TL) FormL5305416 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4061107 Head Manufacturer Lot Number(s)1 2
Rebar Size#5 Headed Bar Model NameHrc 110
Size of HeadReduced Size - 4x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC Rebar Nucor
Head ManufacturerHRC Head FabricatorHRC
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-12-29-4-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/09/2017Fred
Yes
01/16/2017Bar Broke; OK Necking
2016-12-29-4-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/09/2017Fred
Yes
01/16/2017Bar Broke; OK Necking
2016-12-29-4-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/09/2017Fred
Yes
01/16/2017Bar Broke; OK Necking
2016-12-29-4-4ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/09/2017Fred
Yes
01/16/2017Bar Broke; OK Necking
2016-12-29-4-5ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/09/2017Fred
Yes
01/16/2017Bar Broke; OK Necking
2016-12-29-4-6ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/09/2017Fred
Yes
01/16/2017Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-12-29-4-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-12-29-4-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-12-29-4-3 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-12-29-4-4 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-12-29-4-5 ASTM A970-15e1 (Verified)