Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-11-17-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 7285
DEA: 040120T4
EFIS: 0400000027
DIST-CO-RTE-PM04-SF-80-12.6/13.9
Award Date11/27/2012
Closeout DateNot set
Work DescriptionCONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES
Location DescriptionTHE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL
QA Service Level1 (Verified on 10/29/2012)

Sample Information

Sample Taken Date11/17/2016 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/18/2016
Sample typeQuality Assurance A brief description of the sampleHeaded Bars
The quantity of what the sample constitutes12 From where was the sample collectedSource
First name of sampler or witnessed byPrakash Last name of sampler or witnessed byPatel
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC HRC Transportation Laboratory (TL) NumberC652008-C652010
Inspector Lot Number from the Transportation Laboratory (TL) FormL1104216 - L1104416 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4060228 Head Manufacturer Lot Number(s)1, 6, 11
Rebar Size8 Headed Bar Model NameHRC 120
Size of HeadReduced Size - 4x Head Connection Type
Head ShapeSquare Rebar ManufacturerCMC
Head ManufacturerHRC Head FabricatorHRC
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-11-17-3-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Arnold, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2016Arnold
Yes
11/21/2016Bar Broke; OK Necking
2016-11-17-3-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Arnold, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2016Arnold
Yes
11/21/2016Bar Broke; OK Necking
2016-11-17-3-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Arnold, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2016Arnold
Yes
11/21/2016Bar Broke; OK Necking
2016-11-17-3-4ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Arnold, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2016Arnold
Yes
11/21/2016Bar Broke; OK Necking
2016-11-17-3-5ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Arnold, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2016Arnold
Yes
11/21/2016Bar Broke; OK Necking
2016-11-17-3-6ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Arnold, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2016Arnold
Yes
11/21/2016Bar Broke; OK Necking
2016-11-17-3-7ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Arnold, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2016Arnold
Yes
11/21/2016Bar Broke; OK Necking
2016-11-17-3-8ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Arnold, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2016Arnold
Yes
11/21/2016Bar Broke; OK Necking
2016-11-17-3-9ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Arnold, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2016Arnold
Yes
11/21/2016Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-11-17-3-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-11-17-3-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-11-17-3-3 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-11-17-3-4 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-11-17-3-5 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-11-17-3-6 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-11-17-3-7 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-11-17-3-8 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-11-17-3-9 ASTM A970-15e1 (Verified)