Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-10-12-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date10/12/2016 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/13/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed bySantos Last name of sampler or witnessed byVargas
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) NumberC952550
Inspector Lot Number from the Transportation Laboratory (TL) FormL10004416 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4059077
Hoop Manufacturer Lot Number(s)188 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop4'-10.75" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-10-12-2-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/14/2016Fred
Yes
10/14/2016Bar Broke; OK Necking
2016-10-12-2-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/14/2016Fred
Yes
10/14/2016Bar Broke; OK Necking
2016-10-12-2-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/14/2016Fred
Yes
10/14/2016Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-10-12-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-12-2-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-12-2-3 CTM 670-December 2013 (Verified)