Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2016-10-01-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 3825
DEA: 07138204
EFIS: 0700000142
DIST-CO-RTE-PM07-LA-47,103-3.5/4.6,0.0/1.1
Award Date06/30/2011
Closeout Date07/14/2022
Work DescriptionREPLACE STEEL BRIDGE WITH CIP PS CONCRETE BOX GIRDER BRIDGE AND RAMPS.
Location DescriptionLOS ANGELES COUNTY IN LONG BEACH AND LOS ANGELES ON ROUTE 47 FROM OCEAN BOULEVARD TO ROUTE 103 JUNCTION AND ON ROUTE 103 FROM ROUTE 47 JUNCTION TO ANAHEIM STREET OVERHEAD
QA Service Level1 (Verified on 03/29/2012)

Sample Information

Sample Taken Date10/01/2016 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/10/2016
Sample typeQuality Control A brief description of the sample6X12
The quantity of what the sample constitutes2 From where was the sample collectedJob Site
First name of sampler or witnessed byJUSTIN Last name of sampler or witnessed byA
Title of samplerASR Telephone number of samplerUnknown
Laboratory sample identification816-83B Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCATALINA PACIFIC Transportation Laboratory (TL) Number193083
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierSR103 ON RAMP
Structure nameCIDH 25A

Material Information

Material TypeConcrete The concrete mix design numberCIDH720ER6
The truck number from where the sample was collected4152 The batch plant ticket number from where the sample was collected901561
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedCHUTE Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-10-01-2-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory10/29/2016Matthew Clayton
Yes
10/29/2016

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-10-01-2-1 ASTM C39-17a (Verified)