Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-10-04-11

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211562
Permit Numbers: 0714NMC2066 0716NRT0711 07166DP2126
DIST-CO-RTE-PM07--134-7.9/7.9
Award Date05/01/2015
Closeout Date09/06/2018
Work DescriptionRemoval and installation of curb median on glendale Ave. Bridge over 134 Fwy.Construct Curb ramps E/B on/off Ramps to Glendale Ave. W/B of ramps at Monterey Rd. along Glendale Ave.& Monterey Rd. Restripe Glendale /Monterey Rd.Upgrade traffic signals.DP is 716-6DP-2126
Location Description134 Fwy, Glendale
QA Service Level1 (Verified on 07/25/2016)

Sample Information

Sample Taken Date10/04/2016 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/12/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes12 From where was the sample collectedFabricator
First name of sampler or witnessed byKevin Last name of sampler or witnessed byChurchill
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTNT Rebar Nucor Transportation Laboratory (TL) NumberC970911
Inspector Lot Number from the Transportation Laboratory (TL) FormL0214416 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)PL14104777, PL16101720, 002116
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size#4,5,5
Diameter of Hoop2'-2", 2'-8", 3'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor Cascade
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-10-04-11-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/12/2016Brian
Yes
10/13/2016ar roke in Heat Affected Area
2016-10-04-11-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/12/2016Brian
Yes
10/13/2016Bar Broke in Heat Affected Area
2016-10-04-11-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/12/2016Brian
Yes
10/13/2016Bar Broke in Heat Affected Area
2016-10-04-11-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/12/2016Brian
Yes
10/13/2016necking okay
2016-10-04-11-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/12/2016Brian
Yes
10/13/2016necking okay
2016-10-04-11-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/12/2016Brian
Yes
10/13/2016necking okay
2016-10-04-11-7CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/12/2016Brian
Yes
10/13/2016Bar Broke in Heat Affected Area
2016-10-04-11-8CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/12/2016Brian
Yes
10/13/2016Bar Broke in Heat Affected Area
2016-10-04-11-9CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/12/2016Brian
Yes
10/13/2016Bar Broke in Heat Affected Area
2016-10-04-11-10CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/12/2016Brian
Yes
10/13/2016Bar Broke in Heat Affected Area

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-10-04-11-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-04-11-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-04-11-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-04-11-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-04-11-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-04-11-6 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-04-11-7 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-04-11-8 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-04-11-9 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-04-11-10 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-04-11-11 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-04-11-12 CTM 670-December 2013 (Verified)