Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2024-04-12-62

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214698
DEA: 120N8904
EFIS: 1214000130
DIST-CO-RTE-PM12-ORA-133-8.3/M9.3
Award Date11/09/2023
Closeout DateNot set
Work DescriptionCONSTRUCT AUXILIARY LANE.
Location DescriptionORANGE COUNTY IN IRVINE FROM ROUTE 133/405 SEPARATION TO IRVINE CENTER DRIVE OVERCROSSING
QA Service Level1 (Verified on 02/22/2021)

Sample Information

Sample Taken Date04/12/2024 Sample Unique Key62
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/24/2024
Sample typeQuality Assurance A brief description of the sample#10 HRC 500/510 Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byAnthony Last name of sampler or witnessed byB
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC Vinton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerVinton Steel
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#10 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)74132985 Rebar Heat Number(s)2213037
Rebar Size 2 Coupler Unique IDTP-17-03

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-04-12-62-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory04/24/2024aauvinen
Yes
04/24/2024Ultimate - Ok Necking
2024-04-12-62-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory04/24/2024aauvinen
Yes
04/24/2024Ultimate - Ok Necking
2024-04-12-62-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory04/24/2024aauvinen
Yes
04/24/2024Ultimate - Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-04-12-62-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-04-12-62-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-04-12-62-3 CTM 670-December 2013 (Verified)