Sample Record

Owner Lab

  • CT HQ - QASI Bay Area Field Office

DIME Sample ID 2024-04-16-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215741
DEA: 01366004
EFIS: 0100000127
DIST-CO-RTE-PM01-HUM-101-80.0/84.0
Award Date12/29/2022
Closeout DateNot set
Work DescriptionIndianola Cutoff UC
Location DescriptionHUMBOLDT COUNTY NEAR EUREKA FROM EUREKA SLOUGH BRIDGE TO BAYSIDE CUTOFF
QA Service Level1 (Verified on 05/17/2021)

Sample Information

Sample Taken Date04/16/2024 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/19/2024
Sample typeQuality Assurance A brief description of the sampleResistance Butt Welded Hoops
The quantity of what the sample constitutes5 Lots of 150 Hoops From where was the sample collectedFabricator
First name of sampler or witnessed byRyan Last name of sampler or witnessed byParr
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameConco Reinforcing Benicia Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB373-043-24 Structure unique identifier
Structure nameEureka Slough

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4135963
Hoop Manufacturer Lot Number(s)H68 Material Standard CodeASTM A706
Material Grade60 Rebar Size#5
Diameter of Hoop1'-6.5" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Arizona
Welding CompanyConco Reinforcing Benicia Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-04-16-2-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory04/22/2024aauvinen
Yes
04/22/2024Broke in Weld
2024-04-16-2-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory04/22/2024aauvinen
Yes
04/22/2024Ok Necking - Broke in Affected Zone
2024-04-16-2-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory04/22/2024aauvinen
Yes
04/22/2024Ok Necking - Broke in Affected Zone
2024-04-16-2-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory04/22/2024aauvinen
Yes
04/22/2024Ok Necking - Broke in Affected Zone

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-04-16-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-04-16-2-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-04-16-2-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-04-16-2-4 CTM 670-December 2013 (Verified)