Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-08-29-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210862
DEA: 031F4004
EFIS: 0300020420
DIST-CO-RTE-PM03-PLA-80-35.1/38.3
Award Date03/10/2016
Closeout Date06/19/2020
Work DescriptionWIDEN EASTBOUND ROADWAY
Location DescriptionWIDEN EASTBOUND ROADWAY
QA Service Level1 (Verified on 10/20/2015)

Sample Information

Sample Taken Date08/29/2016 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/29/2016
Sample typeQuality Assurance A brief description of the sampleLenton Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byKen Last name of sampler or witnessed byHaas
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Erico Transportation Laboratory (TL) NumberC874905
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerErico Intermediate Assembler or FabricatorUnknown
Rebar Size4 Coupler ModelLenton Formsaver
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)L8802 Rebar Heat Number(s)4056574
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-08-29-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/30/2016Brian
Yes
08/31/2016Service Splice
2016-08-29-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/30/2016Brian
Yes
08/31/2016Service Splice
2016-08-29-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/30/2016Brian
Yes
08/31/2016Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-08-29-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-08-29-1-2 CTM 670-December 2013 (Verified)