Sample Record

Owner Lab

  • Sequoia Consultants

DIME Sample ID 2024-02-15-51

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 993551
DEA: 07279124
EFIS: 0715000076
DIST-CO-RTE-PM07-LA-57-60-R4.3/R4.5
Award Date01/12/2023
Closeout DateNot set
Work DescriptionSTATE ROUTE 57 and 60 HIGHWAYS CONFLUENCE CHOKEPOINT RELIEF PROJECT PHASE II
Location DescriptionCITY of DIAMOND BAR and CITY of INDUSTRY LOS ANGELES COUNTY, CALIFORNIA
QA Service Level2 (Verified on 02/04/2022)

Sample Information

Sample Taken Date02/15/2024 Sample Unique Key51
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/15/2024
Sample typeQuality Control A brief description of the sample1x4 concrete aggregates
The quantity of what the sample constitutes1 per batch From where was the sample collectedSupplier
First name of sampler or witnessed byWilliam Last name of sampler or witnessed bySpigner
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRobertson's RM - Pomona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0072
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedstockpile or belt cut
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-02-15-51-1CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven DryingEddie Mendez, Sequoia Consultants02/21/2024Cassidy Pham
Yes
04/05/2024
2024-02-15-51-2CTM 217-June 2011: Method of Test for Sand EquivalentEddie Mendez, Sequoia Consultants02/21/2024Cassidy Pham
Yes
04/05/2024
2024-02-15-51-3CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)Eddie Mendez, Sequoia Consultants02/21/2024Cassidy Pham
Yes
04/05/2024
2024-02-15-51-4CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesEddie Mendez, Sequoia Consultants02/21/2024Cassidy Pham
Yes
04/05/2024
2024-02-15-51-5CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesEddie Mendez, Sequoia Consultants02/21/2024Cassidy Pham
Yes
04/05/2024

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-02-15-51-1 CTM 226-July 2010 (Verified)
DIME Test ID: 2024-02-15-51-2 CTM 217-June 2011 (Verified)
DIME Test ID: 2024-02-15-51-3 CTM 227-December 2014 (Verified)
DIME Test ID: 2024-02-15-51-4 CTM 202-November 2011 (Verified)
DIME Test ID: 2024-02-15-51-5 CTM 202-November 2011 (Verified)