Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2016-08-15-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 3825
DEA: 07138204
EFIS: 0700000142
DIST-CO-RTE-PM07-LA-47,103-3.5/4.6,0.0/1.1
Award Date06/30/2011
Closeout Date07/14/2022
Work DescriptionREPLACE STEEL BRIDGE WITH CIP PS CONCRETE BOX GIRDER BRIDGE AND RAMPS.
Location DescriptionLOS ANGELES COUNTY IN LONG BEACH AND LOS ANGELES ON ROUTE 47 FROM OCEAN BOULEVARD TO ROUTE 103 JUNCTION AND ON ROUTE 103 FROM ROUTE 47 JUNCTION TO ANAHEIM STREET OVERHEAD
QA Service Level1 (Verified on 03/29/2012)

Sample Information

Sample Taken Date08/15/2016 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/22/2016
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes2 From where was the sample collectedJob Site
First name of sampler or witnessed byJustin Last name of sampler or witnessed byAkabogu
Title of samplerAssistant Structure Representative Telephone number of samplerUnknown
Laboratory sample identification816-72 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameNational Ready Mix Concrete Company Transportation Laboratory (TL) Number193072
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierCOLUMN 10B AND 7B
Structure nameSCHUYLER HEIM BRIDGE

Material Information

Material TypeConcrete The concrete mix design numberS77047 REV1
The truck number from where the sample was collected442 The batch plant ticket number from where the sample was collected185121
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedWheel Barrow from Chute Where the material sample would have been placed if not sampledCOLUMN 10B AND 7B CRASHWALL ND OFF RAMP
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions