Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2024-04-03-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994443
DEA: 053307C4
EFIS: 0514000028
DIST-CO-RTE-PM05-SLO-41,46-44.5/45.3,54.0/57.8
Award Date02/27/2023
Closeout DateNot set
Work DescriptionWye Segment - Route 41/46 Separation
Location DescriptionNot set
QA Service Level1 (Verified on 12/16/2022)

Sample Information

Sample Taken Date04/03/2024 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/11/2024
Sample typeQuality Assurance A brief description of the sample#8 x 5'-2" dia.
The quantity of what the sample constitutes4 lots (476 pcs.) From where was the sample collectedFabricator
First name of sampler or witnessed byOsiel Last name of sampler or witnessed byRamirez
Title of samplerQuality Assurance Inspector Telephone number of sampler(916) 767-3535
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC San Bernardino Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL123-022-24 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)9001778
Hoop Manufacturer Lot Number(s)Lots 1 and 3 Material Standard CodeASTM A706
Material Grade60 Rebar Size#8
Diameter of Hoop5'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Steel Arizona
Welding CompanyCMC Rebar San Bernardino Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-04-03-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory04/12/2024aauvinen
Yes
04/15/2024Ok Necking
2024-04-03-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory04/12/2024aauvinen
Yes
04/15/2024Ok Necking
2024-04-03-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory04/12/2024aauvinen
Yes
04/15/2024Ok Necking
2024-04-03-3-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory04/12/2024aauvinen
Yes
04/15/2024Ok Necking
2024-04-03-3-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory04/12/2024aauvinen
Yes
04/15/2024Ok Necking
2024-04-03-3-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory04/12/2024aauvinen
Yes
04/15/2024Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-04-03-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-04-03-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-04-03-3-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-04-03-3-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-04-03-3-5 CTM 670-December 2013 (Verified)