Sample Record

Owner Lab

  • Alta Vista Solutions - Whittier

DIME Sample ID 2024-03-21-45

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214649
DEA: 07316004
EFIS: 0715000194
DIST-CO-RTE-PM07-LA-14-60.70
Award Date02/07/2023
Closeout DateNot set
Work DescriptionREHABILITATION FOR THE ON/OFF RAMPS AND ADJACENT SHOULDERS. UPGRADING METAL BEAM GUARDRAILS, AC DIKES, SIGN PANELS, CURB RAMPS, TRAFFIC LOOPS DETECTORS, AND SOME OTHER HIGHWAY APPURTENANCES.
Location DescriptionROUTE 14 FROM PALMDALE BLVD TO KERN COUNTRY LINE.
QA Service Level1 (Verified on 01/29/2020)

Sample Information

Sample Taken Date03/21/2024 Sample Unique Key45
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/21/2024
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes10 cubic yards From where was the sample collectedSource
First name of sampler or witnessed byAleksey Last name of sampler or witnessed bySouglobov
Title of sampler Telephone number of sampler
Laboratory sample identification24-0302 Linked DIME Sample ID
The fabricator/manufacturer/facility nameN/A Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberSCI-12622-1
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected29
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedwheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-03-21-45-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersAleksey Souglobov, Alta Vista Solutions - Whittier03/21/2024SoCal Reports
Yes
03/25/2024
2024-03-21-45-2CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteAlberto Pineda-Gonzalez, Alta Vista Solutions - Whittier02/08/2024SoCal Reports
Yes
03/25/2024
2024-03-21-45-3CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodAlberto Pineda-Gonzalez, Alta Vista Solutions - Whittier02/08/2024SoCal Reports
Yes
03/25/2024

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-03-21-45-1 CTM 521-June 2020 (Verified)
DIME Test ID: 2024-03-21-45-2 CTM 557-June 2020 (Verified)