Sample Record
Owner Lab
- CT HQ - QASI Bay Area Field Office
DIME Sample ID 2024-03-25-1
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 994574 DEA: 050C7334 EFIS: 0518000116 |
---|---|
DIST-CO-RTE-PM | 05-SCR-1-10.5/13.4 |
Award Date | 06/29/2023 |
Closeout Date | Not set |
Work Description | CONSTRUCT OVERCROSSING AND AUXILIARY LANE/ Replace Capitola Ave OC + RWs and SWs |
Location Description | SANTA CRUZ COUNTY IN AND NEAR CITY OF CAPITOLA FROM STATE PARK DRIVE OVERCROSSING TO 0.2 MILE NORTH OF BAY AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 04/13/2023) |
Sample Information
Sample Taken Date | 03/25/2024 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/25/2024 |
Sample type | Authorization | A brief description of the sample | ASTM A615 Gr 75 bar |
The quantity of what the sample constitutes | 1 Lot | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Ryan | Last name of sampler or witnessed by | Parr |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Z Systems | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B373-027-24 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
Threaded Bar Type | Deformed | Rebar Size | #9 |
Nut Specification for Threaded Bar | ASTM A897 | System Manufacturer | Z Systems |
Epoxy Coating Color | NA | Threaded Bar Application | Soil Nail |
Coating Standards | Uncoated | Bar Heat Number(s) | A216934 |
Nut Heat Number(s) | L193 | Bar Lot Number | |
Nut Lot Number | Coupler Heat Number(s) | ||
Coupler Grade |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2024-03-25-1-1 ASTM A615-20 (Verified)
DIME Test ID: 2024-03-25-1-2 ASTM A615-20 (Verified)