Sample Record

Owner Lab

  • CT HQ - QASI Bay Area Field Office

DIME Sample ID 2024-03-25-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994574
DEA: 050C7334
EFIS: 0518000116
DIST-CO-RTE-PM05-SCR-1-10.5/13.4
Award Date06/29/2023
Closeout DateNot set
Work DescriptionCONSTRUCT OVERCROSSING AND AUXILIARY LANE.
Location DescriptionSANTA CRUZ COUNTY IN AND NEAR CITY OF CAPITOLA FROM STATE PARK DRIVE OVERCROSSING TO 0.2 MILE NORTH OF BAY AVENUE UNDERCROSSING
QA Service Level1 (Verified on 04/13/2023)

Sample Information

Sample Taken Date03/25/2024 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/25/2024
Sample typeAuthorization A brief description of the sampleASTM A615 Gr 75 bar
The quantity of what the sample constitutes1 Lot From where was the sample collectedSupplier
First name of sampler or witnessed byRyan Last name of sampler or witnessed byParr
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameZ Systems Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB373-027-24 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar TypeDeformed Rebar Size#9
Nut Specification for Threaded BarASTM A897 System ManufacturerZ Systems
Epoxy Coating ColorNA Threaded Bar ApplicationSoil Nail
Coating StandardsUncoated Bar Heat Number(s)A216934
Nut Heat Number(s)L193 Bar Lot Number
Nut Lot Number Coupler Heat Number(s)
Coupler Grade

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-03-25-1-1ASTM A615-20: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory03/26/2024aauvinen
Yes
03/27/2024A615 Bar and Nut
2024-03-25-1-2ASTM A615-20: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory03/26/2024aauvinen
Yes
03/27/2024A615 Bar and Nut

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-03-25-1-1 ASTM A615-20 (Verified)