Sample Record

Owner Lab

  • Alta Vista Solutions - Whittier

DIME Sample ID 2024-03-17-10

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994962
DEA: 07357304
EFIS: 0719000062
DIST-CO-RTE-PM07-LA-5-6.6/13.1
Award Date04/27/2023
Closeout DateNot set
Work DescriptionREPLACE CONCRETE SLABS AND MEDIAN BARRIER,
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS, DOWNEY AND CITY OF COMMERCE FROM 0.2 MILE SOUTH OF ROUTE 5/605 SEPARATION TO 0.1 MILE NORT
QA Service Level1 (Verified on 07/13/2023)

Sample Information

Sample Taken Date03/17/2024 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/17/2024
Sample typeQuality Assurance A brief description of the sample3 RSC beams
The quantity of what the sample constitutes10 cubic yards From where was the sample collectedJob Site
First name of sampler or witnessed byAleksey Last name of sampler or witnessed bySouglobov
Title of sampler Telephone number of sampler
Laboratory sample identification24-0455 Linked DIME Sample ID
The fabricator/manufacturer/facility nameN/A Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberCTS-65-EHI
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected2
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedwheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-03-17-10-1CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength ConcreteSoCal Reports, Alta Vista Solutions - Whittier03/20/2024SoCal Reports
Yes
03/21/2024
2024-03-17-10-2CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteAleksey Souglobov, Alta Vista Solutions - Whittier03/17/2024SoCal Reports
Yes
03/21/2024

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-03-17-10-1 CTM 524-March 2013 (Verified)
DIME Test ID: 2024-03-17-10-2 CTM 557-June 2020 (Verified)