Sample Record

Owner Labs

  • CT SC - 3674 - Pacifica 2
  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2024-03-06-19

Project Information

Project IdentifiersProject ID: 994242
DEA: 042J7404
EFIS: 0415000010
DIST-CO-RTE-PM04-SM-101-0.9/23.4
Award Date02/08/2023
Closeout DateNot set
Work DescriptionREMOVE BRIDGES (PORTIONS), BRIDGE BARRIERS, CONCRETE BARRIERS, & HMA.
Location DescriptionSAN MATEO COUNTY AT VARIOUS LOCATIONS FROM UNIVERSITY AVENUE OVERCROSSING TO SIERRA POINT OFF RAMP OVERCROSSING
QA Service Level1 (Verified on 09/28/2022)

Sample Information

Sample Taken Date03/06/2024 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/15/2024
Sample typeQuality Control A brief description of the sampleType II/V Portland Cement
The quantity of what the sample constitutes72 CY - 48(F) Structural concrete bridge From where was the sample collectedJob Site
First name of sampler or witnessed bySeyoum Last name of sampler or witnessed byWorkenh
Title of samplerASR Telephone number of sampler650-222-7209
Laboratory sample identificationSacramento Linked DIME Sample ID2024-03-06-5
The fabricator/manufacturer/facility nameGraniterock Redwood City Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier35-0131S
Structure nameSierra point off-ramp separation bridge

Material Information

Material TypeConcrete The concrete mix design number577750
The truck number from where the sample was collectedLoad 1 Truck 2420 The batch plant ticket number from where the sample was collected121511
Concrete batch plantGraniterock Redwood City Plant The fabricator/manufacturer designation for the sampleMix
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampledWest Portion of barrier rail on the Bridge
From Lot No.3 Bag Lot No.121511

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-03-06-19-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensSA, CT HQ - Sacramento Concrete Testing Laboratory04/03/2024SA
Yes
04/03/2024

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-03-06-19-1 ASTM C39-17a (Verified)