Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2016-06-27-11
Project Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 06/27/2016 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/04/2016 |
Sample type | Authorization | A brief description of the sample | HY Ten Coupler |
The quantity of what the sample constitutes | 12 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Richard | Last name of sampler or witnessed by | Webster |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | HY Ten Reinforcement | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | HY Ten |
Coupler Manufacturer | HY Ten | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | #6, 8, 14 | Coupler Model | HTLT |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | 6, 8, 14, HTL | Rebar Heat Number(s) | 4048405, 4050513, 3055577 |
Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2016-06-27-11-1 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/03/2016 | Brian | No | necking okay | Info | |
2016-06-27-11-2 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/04/2016 | Brian | No | necking okay | Info | |
2016-06-27-11-3 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/10/2016 | Brian | No | 10K Break | Info | |
2016-06-27-11-4 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/10/2016 | Brian | No | 100 Cycle | Info | |
2016-06-27-11-5 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/10/2016 | Brian | No | HTL Break | Info | |
2016-06-27-11-6 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/10/2016 | Brian | No | HTL Break | Info | |
2016-06-27-11-7 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/10/2016 | Brian | No | 10K Break | Info | |
2016-06-27-11-8 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/10/2016 | Brian | No | 100 Cycle | Info | |
2016-06-27-11-9 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/10/2016 | Brian | No | HTL Break | Info | |
2016-06-27-11-10 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/10/2016 | Brian | No | HTL Break | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2016-06-27-11-1 CTM 670-December 2013
DIME Test ID: 2016-06-27-11-2 CTM 670-December 2013
DIME Test ID: 2016-06-27-11-3 CTM 670-December 2013
DIME Test ID: 2016-06-27-11-4 CTM 670-December 2013
DIME Test ID: 2016-06-27-11-5 CTM 670-December 2013
DIME Test ID: 2016-06-27-11-6 CTM 670-December 2013
DIME Test ID: 2016-06-27-11-7 CTM 670-December 2013
DIME Test ID: 2016-06-27-11-8 CTM 670-December 2013
DIME Test ID: 2016-06-27-11-9 CTM 670-December 2013
DIME Test ID: 2016-06-27-11-10 CTM 670-December 2013