Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2024-02-09-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994326
DEA: 051C3604
EFIS: 0512000134
DIST-CO-RTE-PM05-SB-217-0.9/1.4
Award Date01/31/2023
Closeout DateNot set
Work DescriptionREPLACE BRIDGE.
Location DescriptionSANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE
QA Service Level1 (Verified on 10/17/2022)

Sample Information

Sample Taken Date02/09/2024 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/20/2024
Sample typeQuality Assurance A brief description of the sample#6 Grip Twist Coupler
The quantity of what the sample constitutes52 From where was the sample collectedFabricator
First name of sampler or witnessed byAdrian Last name of sampler or witnessed bySanchez
Title of sampler Telephone number of sampler2137133499
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameIntegrity Rebar Placers Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL159-022-24 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerBarsplice Intermediate Assembler or Fabricator
Rebar Size#6 Coupler ModelGriptwist
Coating StandardsASTM A775 epoxy Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)C210603 Rebar Heat Number(s)1202046437
Rebar Size 2 Coupler Unique IDSS-17-05

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-02-09-2-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory02/21/2024aauvinen
Yes
02/21/2024Service Splice
2024-02-09-2-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory02/21/2024aauvinen
Yes
02/21/2024Service Splice
2024-02-09-2-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory02/21/2024aauvinen
Yes
02/21/2024Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-02-09-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-02-09-2-2 CTM 670-December 2013 (Verified)