Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-07-21-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209135
DEA: 04235844
EFIS: 0400000684
COOP: 042493
DIST-CO-RTE-PM04-SM-101-16.3/17.06
Award Date06/25/2014
Closeout Date12/17/2019
Work DescriptionRECONSTRUCT OVERCROSSING, RETAINING WALLS, GROUND IMPROVEMENT,
Location DescriptionBURLINGAME
QA Service Level1 (Verified on 10/03/2013)

Sample Information

Sample Taken Date07/21/2016 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/22/2016
Sample typeQuality Assurance A brief description of the sampleBarGrip XL Coupler
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byMacasio Last name of sampler or witnessed byCasas
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameBarsplice, Nucor Transportation Laboratory (TL) NumberC581396
Inspector Lot Number from the Transportation Laboratory (TL) FormN/A Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerBarsplice Intermediate Assembler or FabricatorUnknown
Rebar Size#6 Coupler ModelBarGrip XL
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)2M60886 Rebar Heat Number(s)PL15108051, PL15208070
Rebar Size 2 NA Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-07-21-4-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/22/2016Fred
Yes
07/25/2016OK Necking
2016-07-21-4-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/22/2016Fred
Yes
07/25/2016OK Necking
2016-07-21-4-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/22/2016Fred
Yes
07/25/2016OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-07-21-4-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-07-21-4-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-07-21-4-3 CTM 670-December 2013 (Verified)