Sample Record

Owner Lab

  • Skanska USA Civil

DIME Sample ID 2024-01-16-42

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994191
DEA: 081G8304
EFIS: 0816000079
DIST-CO-RTE-PM08-SBD-40-R100.8/R101.8
Award Date12/01/2022
Closeout DateNot set
Work DescriptionHMA, STRUCTURAL CONC, BAR REINFORCING STEEL, CRSP & IMPORTED BORROW.
Location DescriptionSAN BERNARDINO COUNTY AT ESSEX FROM 1.1 MILES EAST OF ESSEX ROAD OVERCROSSING TO 0.5 MILE EAST OF HALFWAY HILLS WASH BRIDGE
QA Service Level1 (Verified on 03/30/2023)

Sample Information

Sample Taken Date01/16/2024 Sample Unique Key42
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/29/2024
Sample typeQuality Assurance A brief description of the sampleHRC Coupler 500/510
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byAmber Last name of sampler or witnessed byChristian
Title of samplerASR Telephone number of sampler928-216-0101
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCamblin Steel Service Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerVinton Steel
Coupler ManufacturerVinton Steel Intermediate Assembler or Fabricator
Rebar Size#9 Coupler ModelHRC 500-510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)Heat 73131267 73131301 Lot 1 Rebar Heat Number(s)2311607
Rebar Size 2 Coupler Unique IDTF-17-01

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-01-16-42-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory01/30/2024aauvinen
Yes
01/31/2024Service Splice
2024-01-16-42-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory01/30/2024aauvinen
Yes
01/31/2024Service Splice
2024-01-16-42-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory01/30/2024aauvinen
Yes
01/31/2024Service Splice
2024-01-16-42-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory01/30/2024aauvinen
Yes
01/31/2024Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-01-16-42-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-01-16-42-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-01-16-42-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-01-16-42-4 CTM 670-December 2013 (Verified)