Sample Record

Owner Labs

  • CT SC - 3672 - Fairfield
  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2016-06-29-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209384
DEA: 04264094
EFIS: 0400000735
COOP: 042531
DIST-CO-RTE-PM04-,SON--
Award Date01/21/2016
Closeout Date06/03/2020
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 06/03/2020)

Sample Information

Sample Taken Date06/29/2016 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/06/2016
Sample typeQuality Assurance A brief description of the sampleType II Cement
The quantity of what the sample constitutesCIDH From where was the sample collectedSource
First name of sampler or witnessed byMelvin Last name of sampler or witnessed byDumlao
Title of samplerTEC Telephone number of sampler5107147638
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameShamrock Transportation Laboratory (TL) Number502
Inspector Lot Number from the Transportation Laboratory (TL) FormTL-502 Structure unique identifierSan Antonio Creek Bridge
Structure nameSan Antonio Creek Bridge

Material Information

Material TypeConcrete The concrete mix design number4700
The truck number from where the sample was collected1295 The batch plant ticket number from where the sample was collected440329
Concrete batch plant04 The fabricator/manufacturer designation for the sampleBatch
A detailed description of where the material sample was collectedwheelbarrow Where the material sample would have been placed if not sampledCIDH Piles
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-06-29-1-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensBang, CT HQ - Sacramento Concrete Testing Laboratory07/27/2016Bang
Yes
07/27/2016

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-06-29-1-1 ASTM C39-17a (Verified)