Sample Record

Owner Lab

  • RMA Group - Rancho Cordova

DIME Sample ID 2023-05-19-118

Project Information

Project IdentifiersProject ID: 215317
DEA: 101J0104
EFIS: 1018000079
DIST-CO-RTE-PM10-CAL,CAL-88,34-34.6/2.2
Award Date05/19/2022
Closeout Date11/16/2023
Work DescriptionConstruct fuel island canopies.
Location DescriptionIn Calaveras and Alpine counties on Route 26 at the West Point Maintenance Station and on Route 88 at the Caples Lake Maintenance Station.
QA Service Level1 (Verified on 07/29/2022)

Sample Information

Sample Taken Date05/19/2023 Sample Unique Key118
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/19/2023
Sample typeQuality Control A brief description of the sampleconcrete
The quantity of what the sample constitutes100 cy From where was the sample collectedJob Site
First name of sampler or witnessed bySpencer Last name of sampler or witnessed byKibbe
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSierra Tahoe Ready Mix Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberD673A
The truck number from where the sample was collected09 The batch plant ticket number from where the sample was collected8733
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedconcrete truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-05-19-118-1CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteSpencer Kibbe, RMA Group - Rancho Cordova05/19/2023Mathew Lowrance
Yes
12/06/2023
2023-05-19-118-2ASTM C143-15a: Standard Test Method for Slump of Hydraulic-Cement ConcreteSpencer Kibbe, RMA Group - Rancho Cordova05/19/2023Mathew Lowrance
No
Info
2023-05-19-118-3CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTodd Strait, RMA Group - Rancho Cordova06/16/2023Mathew Lowrance
Yes
12/06/2023

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-05-19-118-1 CTM 557-June 2020 (Verified)
DIME Test ID: 2023-05-19-118-2 ASTM C143-15a
DIME Test ID: 2023-05-19-118-3 CTM 521-June 2020 (Verified)