Sample Record

Owner Lab

  • RMA Group - Rancho Cordova

DIME Sample ID 2023-04-01-10

Project Information

Project IdentifiersProject ID: 215396
DEA: 042K8404
EFIS: 0417000031
DIST-CO-RTE-PM04-SOL-29,80-0.0,0.8/1.6
Award Date03/26/2021
Closeout Date02/16/2024
Work DescriptionHMA, STRUCTURAL CONCRETE, CIDH PILING AND REBAR.
Location DescriptionSOLANO COUNTY IN VALLEJO AT ROUTE 80/29 SEPARATION AND ON ROUTE 80 FROM 0.2 MILE NORTH OF CARQUINEZ BRIDGE TOLL PLAZA TO 0.3 MILE SOUTH OF MAGAZINE STREET OVERCROSSING
QA Service Level1 (Verified on 01/25/2021)

Sample Information

Sample Taken Date04/01/2023 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/01/2023
Sample typeQuality Control A brief description of the sampleconcrete
The quantity of what the sample constitutes100 cy From where was the sample collectedJob Site
First name of sampler or witnessed byErik Last name of sampler or witnessed byHaagensen
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCentral Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberD101C5RS
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected03094102
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedconcrete truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-04-01-10-1CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteErik Haagensen, RMA Group - Rancho Cordova04/01/2023Mathew Lowrance
Yes
12/04/2023
2023-04-01-10-2ASTM C143-15a: Standard Test Method for Slump of Hydraulic-Cement ConcreteErik Haagensen, RMA Group - Rancho Cordova04/01/2023Mathew Lowrance
Yes
12/04/2023
2023-04-01-10-3CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTodd Strait, RMA Group - Rancho Cordova04/28/2023Mathew Lowrance
Yes
12/04/2023
2023-04-01-10-4CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTodd Strait, RMA Group - Rancho Cordova04/29/2023Mathew Lowrance
Yes
12/04/2023

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-04-01-10-1 CTM 557-June 2020 (Verified)
DIME Test ID: 2023-04-01-10-2 ASTM C143-15a (Verified)
DIME Test ID: 2023-04-01-10-3 CTM 521-June 2020 (Verified)
DIME Test ID: 2023-04-01-10-4 CTM 521-June 2020 (Verified)