Sample Record
Owner Lab
- CT D05 - Carpinteria Field Laboratory
DIME Sample ID 2023-12-04-3
Project Information
Project Identifiers | Project ID: 2720 DEA: 050N7204 EFIS: 0500000227 MINOR: 05A1245 |
---|---|
DIST-CO-RTE-PM | 05--- |
Award Date | Not set |
Closeout Date | 03/18/2020 |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 11/08/2019) |
Sample Information
Sample Taken Date | 12/04/2023 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/04/2023 |
Sample type | Quality Assurance | A brief description of the sample | 4x8 concrete cylinders |
The quantity of what the sample constitutes | 8 CUBIC YARDS | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Eduardo | Last name of sampler or witnessed by | Gomez |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CEMEX Santa Barbara | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 1614705 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 31036289 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Drainage System #24 | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2023-12-04-3-1 | ASTM C1064-12: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete | Eduardo Gomez, CT D05 - Carpinteria Field Laboratory | 12/04/2023 | Doug Ruff | No | Info | ||
2023-12-04-3-2 | ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete | Eduardo Gomez, CT D05 - Carpinteria Field Laboratory | 12/04/2023 | Doug Ruff | No | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2023-12-04-3-1 ASTM C1064-12
DIME Test ID: 2023-12-04-3-2 ASTM C143-20