Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-06-09-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210277
DEA: 051F8904
EFIS: 0514000072
DIST-CO-RTE-PM05-MON-1-28.0/28.4
Award Date05/13/2015
Closeout Date02/01/2018
Work DescriptionCONSTRUCT VIADUCT.
Location DescriptionMONTEREY COUNTY NEAR LUCIA FROM 0.1 MILE SOUTH OF BIG CREEK BRIDGE TO 2.8 MILES SOUTH OF DOLAN CREEK BRIDGE
QA Service Level1 (Verified on 06/01/2015)

Sample Information

Sample Taken Date06/09/2016 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/09/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byEd Last name of sampler or witnessed byFleming
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris Salinas Transportation Laboratory (TL) NumberC711152
Inspector Lot Number from the Transportation Laboratory (TL) FormB1025916 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)SE13100039
Hoop Manufacturer Lot Number(s)H06 Material Standard CodeASTM A706
Material Grade60 Rebar Size6
Diameter of Hoop3'-3" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerHarris Salinas
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-06-09-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/10/2016Brian
Yes
06/10/2016Bar Broke; OK Necking
2016-06-09-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/10/2016Brian
Yes
06/10/2016Bar Broke; OK Necking
2016-06-09-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/10/2016Brian
Yes
06/10/2016Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-06-09-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-09-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-09-3-3 CTM 670-December 2013 (Verified)