Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-06-06-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210698
DEA: 11299204
EFIS: 1100000422
DIST-CO-RTE-PM11-SD-94,805-Var
Award Date10/13/2015
Closeout Date09/10/2018
Work DescriptionSEISMIC RETROFIT 4 BRIDGES ON ROUTES 94 AND 805.
Location DescriptionIN SAN DIEGO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 01/13/2016)

Sample Information

Sample Taken Date06/06/2016 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/08/2016
Sample typeQuality Assurance A brief description of the sample Couplers
The quantity of what the sample constitutes4 From where was the sample collectedSource
First name of sampler or witnessed byHamid Last name of sampler or witnessed byAkbarzadegan
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namePacific Steel Transportation Laboratory (TL) NumberC958028
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerHRC Intermediate Assembler or FabricatorUnknown
Rebar Size#9 Coupler Model500-510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorNucor
Coupler Component Heat/Lot Number(s)0K1753, 75061855 Rebar Heat Number(s)PL16201548, PL16101523
Rebar Size 2 NA Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-06-06-4-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip), CT HQ - Sacramento Structural Materials Testing Laboratory06/09/2016
Yes
06/09/2016Bar Broke,Ok Necking
2016-06-06-4-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip), CT HQ - Sacramento Structural Materials Testing Laboratory06/09/2016
Yes
06/09/2016Bar Broke,Ok necking
2016-06-06-4-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip), CT HQ - Sacramento Structural Materials Testing Laboratory06/09/2016
Yes
06/09/2016Bar Broke,Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-06-06-4-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-06-4-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-06-4-3 CTM 670-December 2013 (Verified)