Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2016-05-24-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210569
DEA: 083555V4
EFIS: 0814000086
DIST-CO-RTE-PM08-SBD-15-42.5/46.0
Award Date11/05/2015
Closeout Date01/18/2022
Work DescriptionWIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR.
Location DescriptionSAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING
QA Service Level1 (Verified on 10/15/2015)

Sample Information

Sample Taken Date05/24/2016 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/25/2016
Sample typeQuality Control A brief description of the sample6x12
The quantity of what the sample constitutes6 From where was the sample collectedJob Site
First name of sampler or witnessed bydarren Last name of sampler or witnessed byhopper
Title of samplerasr Telephone number of samplerUnknown
Laboratory sample identification934-04 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameRobertson Transportation Laboratory (TL) Number180604
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierRETAINING WALL 160
Structure nameFOOTING STEPS 1 TO 7

Material Information

Material TypeConcrete The concrete mix design numberSC590B38
The truck number from where the sample was collected1712 The batch plant ticket number from where the sample was collected1086271
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedPUMP TREMIE Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-05-24-6-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory05/31/2016Matthew Clayton
Yes
05/31/2016
2016-05-24-6-2ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory06/07/2016Matthew Clayton
Yes
06/07/2016
2016-05-24-6-3ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory06/21/2016Matthew Clayton
Yes
06/21/2016

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-05-24-6-1 ASTM C39-17a (Verified)
DIME Test ID: 2016-05-24-6-2 ASTM C39-17a (Verified)
DIME Test ID: 2016-05-24-6-3 ASTM C39-17a (Verified)