Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-05-17-1

Project Information

Project IdentifiersProject ID: 7285
DEA: 040120T4
EFIS: 0400000027
DIST-CO-RTE-PM04-SF-80-12.6/13.9
Award Date11/27/2012
Closeout DateNot set
Work DescriptionCONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES
Location DescriptionTHE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL
QA Service Level1 (Verified on 10/29/2012)

Sample Information

Sample Taken Date05/17/2016 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/18/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes150 From where was the sample collectedJob Site
First name of sampler or witnessed byKevin Last name of sampler or witnessed byChurchill
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Rbar Transportation Laboratory (TL) NumberC952966
Inspector Lot Number from the Transportation Laboratory (TL) FormL0203316 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingRetest
Service or UltimateUltimate Rebar Heat Number(s)4054955
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop2'-1" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-05-17-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Bryan, CT HQ - Sacramento Structural Materials Testing Laboratory05/19/2016Bryan
No
Bar Broke; OK Necking Info
2016-05-17-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Bryan, CT HQ - Sacramento Structural Materials Testing Laboratory05/19/2016Bryan
No
Bar Broke; OK Necking Info
2016-05-17-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Bryan, CT HQ - Sacramento Structural Materials Testing Laboratory05/19/2016Bryan
No
Bar Broke; OK Necking Info
2016-05-17-1-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Bryan, CT HQ - Sacramento Structural Materials Testing Laboratory05/19/2016Bryan
No
Bar Broke; OK Necking Info

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-05-17-1-1 CTM 670-December 2013
DIME Test ID: 2016-05-17-1-2 CTM 670-December 2013
DIME Test ID: 2016-05-17-1-3 CTM 670-December 2013