Sample Record

Owner Lab

  • CT D09 - Bishop Field Laboratory

DIME Sample ID 2023-10-18-23

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994330
DEA: 09366404
EFIS: 0916000006
DIST-CO-RTE-PM09-MNO-395-58.2/60.4
Award DateNot set
Closeout DateNot set
Work DescriptionHOT MIX ASPHALT (TYPE A), IMPORTED BORROW, AND ROADWAY EXCAVATION.
Location DescriptionMONO COUNTY ABOUT 6 MILES NORTH OF LEE VINING FROM ROUTE 167 TO 0.4 MILE NORTH OF CONWAY RANCH ROAD
QA Service Level1 (Verified on 07/31/2023)

Sample Information

Sample Taken Date10/18/2023 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/19/2023
Sample typeAcceptance A brief description of the sample3600 Psi / 7-11 Mix
The quantity of what the sample constitutes16 Cubic Yards From where was the sample collectedJob Site
First name of sampler or witnessed byJeffery Last name of sampler or witnessed byPuente
Title of samplerQA Telephone number of sampler6614400636
Laboratory sample identificationConc-05 Linked DIME Sample ID
The fabricator/manufacturer/facility name7-11 Materials Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number750416A6
The truck number from where the sample was collected89393 The batch plant ticket number from where the sample was collected853439
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDS-1 Headwall Outlet Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-10-18-23-1ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensDerek Carrington, CT D09 - Bishop Field Laboratory10/23/2023Derek Carrington
Yes
10/23/2023DS-1 Headwall Outlet
2023-10-18-23-2ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensDerek Carrington, CT D09 - Bishop Field Laboratory11/15/2023Derek Carrington
Yes
11/16/2023PCC-05

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-10-18-23-1 ASTM C39-18 (Verified)
DIME Test ID: 2023-10-18-23-2 ASTM C39-18 (Verified)