Sample Record
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
DIME Sample ID 2016-04-05-14
Project Information
Project Identifiers | Project ID: 208714 DEA: 08043514 EFIS: 0800000010 |
---|---|
DIST-CO-RTE-PM | 08-SBD-58-R22.2/R31.1 |
Award Date | 12/30/2014 |
Closeout Date | 08/29/2018 |
Work Description | REALIGN AND WIDEN 2 TO 4 LANES EXPRESSWAY |
Location Description | HINKLEY ROAD FROM 2.4 MILES WEST OF HIDDEN RIVER ROAD TO? 0.7 MILE EAST OF LENWOOD ROAD. |
QA Service Level | 1 (Verified on 03/22/2013) |
Sample Information
Sample Taken Date | 04/05/2016 | Sample Unique Key | 14 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/07/2016 |
Sample type | Department Acceptance | A brief description of the sample | Class 2 Aggregate Subbase |
The quantity of what the sample constitutes | Unknown | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Larry | Last name of sampler or witnessed by | Francisco |
Title of sampler | TE | Telephone number of sampler | Unknown |
Laboratory sample identification | 6114B | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Robertsons Barstow | Transportation Laboratory (TL) Number | C 951239 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Unknown |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Sta 1558 00 A1 Line East of Dixie Rd |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2016-04-05-14-1 | CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates | Jose Guzman, CT D08 - Fontana Southern Regional Laboratory | 04/07/2016 | Charles Mcdonald | No | Info | ||
2016-04-05-14-2 | CTM 217-June 2011: Method of Test for Sand Equivalent | Jose Guzman, CT D08 - Fontana Southern Regional Laboratory | 04/07/2016 | Charles Mcdonald | No | Info | ||
2016-04-05-14-3 | CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer | MD Shahjahan, CT D08 - Fontana Southern Regional Laboratory | 04/13/2016 | Charles Mcdonald | No | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2016-04-05-14-1 CTM 202-November 2011
DIME Test ID: 2016-04-05-14-2 CTM 217-June 2011
DIME Test ID: 2016-04-05-14-3 CTM 301-March 2000