Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2023-10-02-59

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214486
DEA: 080K1224
EFIS: 0815000244
DIST-CO-RTE-PM08-SBD-15-R28.6/37.5
Award DateNot set
Closeout DateNot set
Work DescriptionREHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT
Location DescriptionSAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date10/02/2023 Sample Unique Key59
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/04/2023
Sample typeVerification A brief description of the sampleModified Asphalt Binder
The quantity of what the sample constitutes1 qt can From where was the sample collectedSource
First name of sampler or witnessed byAlex Last name of sampler or witnessed byAlex QC
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAgcon/ Calportland/ Blue Diamond/ LHoist/ SJR Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-34 M
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierCentennial Asphalt - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-10-02-59-1AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)Sm Ali, CT D08 - Fontana Southern Regional Laboratory10/16/2023Sm Ali
Yes
12/28/2023- 0.037 + 0.006 = - 0.031
2023-10-02-59-2AASHTO T315-12: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)Sunday Agude, CT D08 - Fontana Southern Regional Laboratory10/16/2023Sunday Agude
Yes
12/28/2023
2023-10-02-59-3AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)Sunday Agude, CT D08 - Fontana Southern Regional Laboratory10/16/2023Sunday Agude
Yes
12/28/2023
2023-10-02-59-4AASHTO T228-09r13: Standard Method of Test for Specific Gravity of Semi-Solid Asphalt Materials (Specific Gravity)Anthony Hernandez, CT D08 - Fontana Southern Regional Laboratory10/16/2023Anthony Hernandez
Yes
12/28/2023
2023-10-02-59-5AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational ViscometerSunday Agude, CT D08 - Fontana Southern Regional Laboratory10/16/2023Sunday Agude
Yes
12/28/2023
2023-10-02-59-7AASHTO T313-22: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)Sunday Agude, CT D08 - Fontana Southern Regional Laboratory11/28/2023Sunday Agude
Yes
12/28/2023
2023-10-02-59-8AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)Sm Ali, CT D08 - Fontana Southern Regional Laboratory11/28/2023Sm Ali
Yes
12/28/2023

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-10-02-59-1 AASHTO T240-17 (Verified)
DIME Test ID: 2023-10-02-59-2 AASHTO T315-12 (Verified)
DIME Test ID: 2023-10-02-59-3 AASHTO T315-16 (Verified)
DIME Test ID: 2023-10-02-59-4 AASHTO T228-09r13 (Verified)
DIME Test ID: 2023-10-02-59-5 AASHTO T316-17 (Verified)
DIME Test ID: 2023-10-02-59-7 AASHTO T313-22 (Verified)
DIME Test ID: 2023-10-02-59-8 AASHTO T315-20 (Verified)