Sample Record

Owner Lab

  • Granite Construction Company - Santa Paula

DIME Sample ID 2023-10-03-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date10/03/2023 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/03/2023
Sample typeAggregate Prequalification Program A brief description of the sample3/8" PG Course aggregate Natural
The quantity of what the sample constitutesFour bags From where was the sample collectedManufacturer
First name of sampler or witnessed byWilliam Last name of sampler or witnessed byLucas
Title of samplerQC Operations Supervisor Telephone number of sampler6619028196
Laboratory sample identification1481283603 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Construction - Big Rock Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0046
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-10-03-7-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesWilliam Lucas, Granite Construction Company - Santa Paula10/03/2023James Hancock
Yes
10/24/2023
2023-10-03-7-2CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)William Lucas, Granite Construction Company - Santa Paula10/03/2023James Hancock
Yes
10/24/2023
2023-10-03-7-3CTM 211-May 2010: Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing MachineWilliam Lucas, Granite Construction Company - Santa Paula10/03/2023James Hancock
Yes
10/24/2023
2023-10-03-7-4CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium SulfateSteven Chang , Granite Construction Company - Santa Paula10/06/2023James Hancock
Yes
10/24/2023Tested by G3 in Cerritos.

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-10-03-7-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2023-10-03-7-2 CTM 227-December 2014 (Verified)
DIME Test ID: 2023-10-03-7-3 CTM 211-May 2010 (Verified)
DIME Test ID: 2023-10-03-7-4 CTM 214-August 2010 (Verified)