Sample Record
Owner Labs
- CT SC - 3672 - Richmond
- CT HQ - Sacramento Concrete Testing Laboratory
DIME Sample ID 2023-09-29-2
Project Information
Project Identifiers | Project ID: 993184 DEA: 040A7724 EFIS: 0420000288 COOP: 042763 |
---|---|
DIST-CO-RTE-PM | 04-ALA-80-6.4/6.8 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Excavation, HMA, structural concrete, minor concrete and drainage. |
Location Description | IN BERKELEY AND ALBANY FROM 0.6 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.3 MILE SOUTH OF EL CERRITO SEPARATION AND OVERHEAD |
QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
Sample Taken Date | 09/29/2023 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 10/10/2023 |
Sample type | Quality Assurance | A brief description of the sample | 4x8 cylinders |
The quantity of what the sample constitutes | 27CY | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Jingan | Last name of sampler or witnessed by | Chen |
Title of sampler | ASR | Telephone number of sampler | 5105063387 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Central Concrete Pinole | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Retaining Wall 175 |
Material Information
Material Type | Concrete | The concrete mix design number | 4E0CG5E1 |
---|---|---|---|
The truck number from where the sample was collected | 6186 | The batch plant ticket number from where the sample was collected | 447075 |
Concrete batch plant | Central Pinole | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | Back of Truck chute | Where the material sample would have been placed if not sampled | RW175 |
From Lot No. | Bag Lot No. |
Submitted Tests