Sample Record
Owner Labs
- CT SC - 3665 - West Sacramento
- CT HQ - Sacramento Concrete Testing Laboratory
DIME Sample ID 2023-09-23-1
Project Information
Project Identifiers | Project ID: 214469 DEA: 030H08U4 EFIS: 0319000029 |
---|---|
DIST-CO-RTE-PM | 03-SAC-50-L0.2/R6.1 |
Award Date | 06/30/2020 |
Closeout Date | Not set |
Work Description | Sac 50 Design Build PLEASE NOTE THAT DESIGN BUILDER MUST PERFORM QUALITY VALIDATION TESTING IN ACCORDANCE WITH THE MATERIAL CONTROL SCHEDULE (MCS) FOR ITEMS SUCH AS STRANDS, HS BOLTS, ELASTOMERIC BEARING PADS, JOINT SEALANTS, COUPLERS & WELDED HOOPS, ETC |
Location Description | FROM 0.1 MILE EAST OF I-5 TO 0.8 MILE EAST OF WATT AVE |
QA Service Level | 1 (Verified on 10/23/2019) |
Sample Information
Sample Taken Date | 09/23/2023 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/25/2023 |
Sample type | Quality Assurance | A brief description of the sample | type II/V |
The quantity of what the sample constitutes | 104 CY | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Artyom | Last name of sampler or witnessed by | Olifir |
Title of sampler | ASR | Telephone number of sampler | 5307085171 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Cemex | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 24-0289R/L | |
Structure name | Brighton Br- Frame 2 Deck Pour |
Material Information
Material Type | Concrete | The concrete mix design number | 1619340 |
---|---|---|---|
The truck number from where the sample was collected | Load 3 Truck 10072285 | The batch plant ticket number from where the sample was collected | 30939088 |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Sample taken from the chute. Middle of pour | Where the material sample would have been placed if not sampled | Frame 2 Deck |
From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2023-09-23-1-4 ASTM C39-17a (Verified)
DIME Test ID: 2023-09-23-1-5 ASTM C39-17a (Verified)
DIME Test ID: 2023-09-23-1-6 ASTM C39-17a (Verified)