Sample Record
Owner Lab
- Sequoia Consultants
DIME Sample ID 2023-08-19-2
Project Information
Project Identifiers | Project ID: 214469 DEA: 030H08U4 EFIS: 0319000029 |
---|---|
DIST-CO-RTE-PM | 03-SAC-50-L0.2/R6.1 |
Award Date | 06/30/2020 |
Closeout Date | Not set |
Work Description | Sac 50 Design Build PLEASE NOTE THAT DESIGN BUILDER MUST PERFORM QUALITY VALIDATION TESTING IN ACCORDANCE WITH THE MATERIAL CONTROL SCHEDULE (MCS) FOR ITEMS SUCH AS STRANDS, HS BOLTS, ELASTOMERIC BEARING PADS, JOINT SEALANTS, COUPLERS & WELDED HOOPS, ETC |
Location Description | FROM 0.1 MILE EAST OF I-5 TO 0.8 MILE EAST OF WATT AVE |
QA Service Level | 1 (Verified on 10/23/2019) |
Sample Information
Sample Taken Date | 08/19/2023 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/20/2023 |
Sample type | Quality Assurance | A brief description of the sample | concrete aggs |
The quantity of what the sample constitutes | 0-420 Approximate CY | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Matthew | Last name of sampler or witnessed by | Menning |
Title of sampler | Materials Tester | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Cemex | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | BR-11 Frame 4 Stem and Soffit |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-57-0008 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Cemex | The fabricator/manufacturer designation for the sample | 1615776 |
The plant number | West Sacramento | A detailed description of where the material sample was collected | Batch Plant |
Where the material sample would have been placed if not sampled | Frame 4 Stem and Soffit | Primary Aggregate Nominal Size | 1 inch |
The concrete mix design number | 1615776 | Lot number | |
Sublot number | Aggregate Mix Number |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
No results found. |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
Test Summary for Concrete Aggregate - 1615776 - RC23-0162 - 081923 | 08/23/2023 | Info |