Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2023-08-18-12

Project Information

Project IdentifiersProject ID: 994326
DEA: 051C3604
EFIS: 0512000134
DIST-CO-RTE-PM05-SB-217-0.9/1.4
Award Date01/31/2023
Closeout DateNot set
Work DescriptionREPLACE BRIDGE.
Location DescriptionSANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE
QA Service Level1 (Verified on 10/17/2022)

Sample Information

Sample Taken Date08/18/2023 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing08/25/2023
Sample typeQuality Assurance A brief description of the sample#8 x 4-8"
The quantity of what the sample constitutes844 From where was the sample collectedManufacturer
First name of sampler or witnessed byadrian Last name of sampler or witnessed bysanchez
Title of sampler Telephone number of sampler2137133499
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL159-222-23 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)1202049191
Hoop Manufacturer Lot Number(s)L1-L6 Material Standard CodeASTM A706
Material Grade60 Rebar Size#8
Diameter of Hoop4'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-08-18-12-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/25/2023aauvinen
Yes
08/25/2023Ok Necking
2023-08-18-12-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/25/2023aauvinen
Yes
08/25/2023Ok Necking
2023-08-18-12-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/25/2023aauvinen
Yes
08/25/2023Ok Necking
2023-08-18-12-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/25/2023aauvinen
Yes
08/25/2023Ok Necking
2023-08-18-12-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/25/2023aauvinen
Yes
08/25/2023Ok Necking
2023-08-18-12-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/25/2023aauvinen
Yes
08/25/2023Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-08-18-12-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-08-18-12-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-08-18-12-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-08-18-12-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-08-18-12-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-08-18-12-6 CTM 670-December 2013 (Verified)