Sample Record

Owner Lab

  • CT D08 - Fontana Field Testing Laboratory

DIME Sample ID 2023-07-14-40

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214337
DEA: 080E33U4
EFIS: 0817000075
DIST-CO-RTE-PM08-SBD-115-R7.3/R10.0
Award Date04/26/2021
Closeout DateNot set
Work DescriptionADD WB AUX & EB DECEL LANES, WIDEN I15 SW CONNECT,RAMPS/BRDG
Location DescriptionSAN BERNARDINO COUNTY IN ONTARIO FROM 0.2 MILE WEST OF CUCAMONGA CREEK BRIDGE TO MILLIKEN AVENUE
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date07/14/2023 Sample Unique Key40
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/15/2023
Sample typeAcceptance A brief description of the sampleConcrete beams
The quantity of what the sample constitutes3 Beams From where was the sample collectedJob Site
First name of sampler or witnessed byNathan Last name of sampler or witnessed byOgbasellasie
Title of sampler Telephone number of sampler
Laboratory sample identification3-A1,3-A2,3-A3 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex, Fontana Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberLB0608SP
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected4
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedback of concrete truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-07-14-40-1CTM 533-June 2010: Method of Test for Ball Penetration in Fresh Portland Cement ConcreteNathan Ogbasellasie, CT D08 - Fontana Field Testing Laboratory07/14/2023Maryanna Landaverde
Yes
08/11/2023
2023-07-14-40-2CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodNathan Ogbasellasie, CT D08 - Fontana Field Testing Laboratory07/14/2023Maryanna Landaverde
Yes
08/11/2023
2023-07-14-40-3CTM 518-June 2010: Method of Test for Unit Weight of Fresh ConcreteNathan Ogbasellasie, CT D08 - Fontana Field Testing Laboratory07/14/2023Maryanna Landaverde
Yes
08/11/2023
2023-07-14-40-4CTM 523-May 2020: Method of Test for Flexural Strength of ConcreteM. Haque / M. Landaverde, CT D08 - Fontana Field Testing Laboratory08/11/2023Maryanna Landaverde
Yes
08/11/2023

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-07-14-40-1 CTM 533-June 2010 (Verified)
DIME Test ID: 2023-07-14-40-2 CTM 504-June 2010 (Verified)
DIME Test ID: 2023-07-14-40-3 CTM 518-June 2010 (Verified)
DIME Test ID: 2023-07-14-40-4 CTM 523-May 2020 (Verified)