Sample Record

Owner Labs

  • CT SC - 3674 - Livermore
  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2023-07-26-63

Project Information

Project IdentifiersProject ID: 209820
DEA: 04297634
EFIS: 0415000040
COOP: 042548
DIST-CO-RTE-PM04-ALA-84,680-17.9/21
Award Date02/19/2021
Closeout DateNot set
Work DescriptionROUTE 84 WIDENING (4-LANE EXPRESSWAY) FROM I-680 TO PIGEON PASS, INCLUDING INTERSECTION, DRAINAGE IMPROVEMENTS AND UTILITY RELOCATION.
Location DescriptionALAMEDA COUNTY IN AND NEAR SUNOL, PLEASANTON, AND LIVERMORE ON ROUTE 84 FROM 0.1 MILE EAST OF ROUTE 680 TO 0.1 MILE SOUTH OF RUBY HILL DRIVE AND ON ROUTE 680 FROM 1.2 MILES SOUTH TO 1.8 MILES NORTH OF ROUTE 84
QA Service Level1 (Verified on 11/04/2019)

Sample Information

Sample Taken Date07/26/2023 Sample Unique Key63
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/04/2023
Sample typeQuality Assurance A brief description of the sample4x8 concrete cylinders
The quantity of what the sample constitutes3 From where was the sample collectedJob Site
First name of sampler or witnessed byMarcos Last name of sampler or witnessed byLopez
Title of samplerASR Telephone number of sampler5104969610
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameN/A Transportation Laboratory (TL) Number169985
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameRW 10

Material Information

Material TypeConcrete The concrete mix design numberD20115EA
The truck number from where the sample was collectedLoad 5 The batch plant ticket number from where the sample was collectedUnkown
Concrete batch plantCentral concrete The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedcement mixer load 5 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-07-26-63-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensSA, CT HQ - Sacramento Concrete Testing Laboratory08/23/2023SA
Yes
08/23/2023

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-07-26-63-1 ASTM C39-17a (Verified)