Sample Record
Owner Lab
- Kie-Con, Incorporated - Antioch
DIME Sample ID 2022-08-19-79
Project Information
Project Identifiers | Project ID: 993169 DEA: 050A0904 EFIS: 0513000028 |
---|---|
DIST-CO-RTE-PM | 05-MON-156-R1.4/R2.0 |
Award Date | 12/14/2021 |
Closeout Date | Not set |
Work Description | WIDEN REINFORCED STRUCTURAL CONCRETE BRIDGE & REPLACE BRIDGE RAILING. |
Location Description | MONTEREY COUNTY IN AND NEAR CASTROVILLE FROM 0.3 MILE EAST OF ROUTE 156/183 SEPARATION TO 0.2 MILE EAST OF CASTROVILLE BOULEVARD |
QA Service Level | 1 (Verified on 08/17/2021) |
Sample Information
Sample Taken Date | 08/19/2022 | Sample Unique Key | 79 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/19/2022 |
Sample type | Quality Control | A brief description of the sample | QC concrete sampling |
The quantity of what the sample constitutes | 19.25CY | From where was the sample collected | Source |
First name of sampler or witnessed by | Connor | Last name of sampler or witnessed by | Pelan |
Title of sampler | QC Inspector | Telephone number of sampler | 7209266089 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Kie-Con Antioch | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Castroville |
Material Information
Material Type | Concrete | The concrete mix design number | K4050900S |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 115582 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Dischard fron concrete truck into wheelbarrow. | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2022-08-19-79-1 | CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement Concrete | Connor Pelan, Kie-Con, Incorporated - Antioch | 08/19/2022 | Connor Pelan | Yes | 08/03/2023 | ||
2022-08-19-79-2 | CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete | Connor Pelan, Kie-Con, Incorporated - Antioch | 08/19/2022 | Connor Pelan | No | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2022-08-19-79-1 CTM 556-January 2018 (Verified)
DIME Test ID: 2022-08-19-79-2 CTM 518-June 2010