Sample Record

Owner Labs

  • CT D04 - Petaluma Field Laboratory
  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2023-08-02-27

Project Information

Project IdentifiersProject ID: 993776
DEA: 040J3004
EFIS: 0413000433
DIST-CO-RTE-PM04-SON-1-26.7/27.1
Award Date07/08/2022
Closeout DateNot set
Work DescriptionCONSTRUCTING RETAINING WALL AND CONFINEMENT SYSTEM TO RESTORE SLIPOUT.
Location DescriptionSONOMA COUNTY NEAR JENNER FROM 0.3 MILE TO 0.7 MILE NORTH OF MEYERS GRADE ROAD
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date08/02/2023 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing08/03/2023
Sample typeQuality Assurance A brief description of the sampleEpoxy Coated #6 Stirrups for Waler
The quantity of what the sample constitutes20 lbs (3 bars) From where was the sample collectedJob Site
First name of sampler or witnessed byKyle Last name of sampler or witnessed byWhittman
Title of samplerASR AND SR Telephone number of sampler925-286-7554
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameFletcher Coating Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier20-E0110
Structure nameSlidesville Retaining Wall

Material Information

Material TypeSMTL TM7 - Epoxy Coated Rebar Rebar Heat Number(s)TBD
Rebar Epoxy Batch Number(s) Rebar Coating SpecificationASTM A934
Rebar Size (#)#6 Rebar Coating ColorPurple
Rebar ManufacturerPJs rebar Rebar CoaterFletcher Coating
Rebar Powder Manufacturer Release Number
Quality Assurance Code

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-08-02-27-1ASTM A934-19: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)David Murray, CT HQ - Sacramento Structural Materials Testing Laboratory08/08/2023David Murray
Yes
08/09/2023Tested bars from field exposed to sunlight. Bar were stirrups, not straight sections as typical for TM7.

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-08-02-27-1 ASTM A934-19 (Verified)