Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2023-07-10-2
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 212720 DEA: 07291404 EFIS: 0712000094 |
---|---|
DIST-CO-RTE-PM | 07-LA-1-55-58 |
Award Date | 02/18/2021 |
Closeout Date | Not set |
Work Description | TRANCAS CREEK BRIDGE REPLACEMENT |
Location Description | IN LOS ANGELES IN CITY OF MALIBU AT TRANCAS CREEK BRIDGE (53-0027). |
QA Service Level | 1 (Verified on 04/02/2021) |
Sample Information
Sample Taken Date | 07/10/2023 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/12/2023 |
Sample type | Quality Assurance | A brief description of the sample | #6 hoop 2'-6" diam. |
The quantity of what the sample constitutes | 1837 Hoops lots 1-13 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Osiel | Last name of sampler or witnessed by | Ramirez |
Title of sampler | Quality Assurance Inspector | Telephone number of sampler | (916) 767-3535 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMC Rebar San Bernardino | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L123-017-23 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4130419 |
Hoop Manufacturer Lot Number(s) | Lots 1, 5, 9, 12 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #6 |
Diameter of Hoop | 2'-6" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC Steel Arizona |
Welding Company | CMC Rebar San Bernardino | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2023-07-10-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-07-10-2-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-07-10-2-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-07-10-2-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-07-10-2-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-07-10-2-6 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-07-10-2-7 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-07-10-2-8 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-07-10-2-9 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-07-10-2-10 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-07-10-2-11 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-07-10-2-12 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-07-10-2-13 CTM 670-December 2013 (Verified)