Sample Record

Owner Lab

  • CT HQ - QASI Bay Area Field Office

DIME Sample ID 2023-06-29-1

Project Information

Project IdentifiersProject ID: 214956
DEA: 042K1704
EFIS: 0416000378
DIST-CO-RTE-PM04-ALA-880,880-15.6/26.5
Award Date01/03/2023
Closeout DateNot set
Work DescriptionCONSTRUCT PVMT, JT SEAL, BARRIER, CL RAILING AND BRIDGE REMOVAL.
Location DescriptionALAMEDA COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 05/08/2020)

Sample Information

Sample Taken Date06/29/2023 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing06/29/2023
Sample typeQuality Assurance A brief description of the sampleBar-Lock Standard Couplers
The quantity of what the sample constitutes4 lots From where was the sample collectedFabricator
First name of sampler or witnessed byRyan Last name of sampler or witnessed byParr
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameC&N Reinforcing Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB373-950-23 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerDayton Superior Intermediate Assembler or Fabricator
Rebar Size#4 Coupler ModelBar-Lock L Series D250L
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)192435 Rebar Heat Number(s)4129224
Rebar Size 2 Coupler Unique IDSL-17-06

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-06-29-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory06/30/2023aauvinen
Yes
06/30/2023Service Splice
2023-06-29-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory06/30/2023aauvinen
Yes
06/30/2023Service Splice
2023-06-29-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory06/30/2023aauvinen
Yes
06/30/2023Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-06-29-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-06-29-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-06-29-1-3 CTM 670-December 2013 (Verified)