Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2015-11-09-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209950
DEA: 080N56U4
EFIS: 0813000176
DIST-CO-RTE-PM08-SBD-40-R94.7/R99.7
Award Date01/22/2015
Closeout Date09/17/2018
Work DescriptionBRIDGE REPLACEMENTS.
Location DescriptionSAN BERNARDINO COUNTY NEAR ESSEX AT HALLER WASH BRIDGE AT ROJO WASH BRIDGE AND AT CLIPPER VALLEY WASH BRIDGE
QA Service Level1 (Verified on 04/29/2015)

Sample Information

Sample Taken Date11/09/2015 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/13/2015
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byJohn Last name of sampler or witnessed byCaron
Title of samplerASR Telephone number of samplerUnknown
Laboratory sample identification907-09 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameRobertsons Transportation Laboratory (TL) Number01109
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design numberRRM15025
The truck number from where the sample was collected1187 1697 The batch plant ticket number from where the sample was collected1309037 1309038
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleBatch plant
A detailed description of where the material sample was collectedWheelbarrow Where the material sample would have been placed if not sampledPier 5 COL
From Lot No.Not set Bag Lot No.Not set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2015-11-09-4-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory11/16/2015Matthew Clayton
Yes
11/16/2015
2015-11-09-4-2ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory12/07/2015Matthew Clayton
Yes
12/07/2015

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2015-11-09-4-1 ASTM C39-17a (Verified)
DIME Test ID: 2015-11-09-4-2 ASTM C39-17a (Verified)